LMM for the Kodiak 100
Page 7-27
190-02102-00 Rev.4
and the calibration setup is correct, this parameter should be near zero, and
fluctuation should be minimal, take note of the range of fluctuation.
4. CALIBRATION DATA:
a) VALUE -the instantaneous current reading from the GEA if the current offset
were zero (any calibration has been taken out).
b) CALIBRATION OFFSET -the instantaneous calculation of what the offset
should be to properly calibrate the channel (assuming the shunt is properly
set up for calibration, see Step 0).
c) CALIBRATION CORRECTED VALUE - the output of the GEA channel if the
above offset were applied (should always be zero).
d) Press the STORE softkey, a confirmation box will be displayed.
Figure 7-8. Calibrate Confirmation Box
e) Press the ENT Key to accept the CALIBRATION OFFSET value, the
instantaneous CALIBRATION OFFSET value will be stored as the CURRENT
OFFSET.
f) The G1000 NXi will now recheck the GEA configuration (this may take several
minutes). During this time the box shown in
will be displayed. Do
not perform any actions until this is complete.
Figure 7-9. Configuration Verification Processing
g) When the configuration is completed, press the ENT Key to confirm.