6.13 Restore from Heartbeat expiration event (en_act_hb_restore)
The M40GBP support automatic or manual heartbeat restore after a heartbeat expiration event.
The default value for the en_act_hb_restore is ON.
When the en_act_hb_restore is ON the M40GBP will restore to
Inline (Normal)
state when the
heartbeat packets will be received from the Monitor port.
When the en_act_hb_restore is OFF the M40GBP preserves its state and no heartbeat packets are
generated.
The following actions should be taken to restore the normal operation:
Restore external environment to normal work.
Send command “set_bypass_mode inline”
Send command “set_hb_act_mode on”
M40GBP$ get_en_act_hb_restore
restore active state: on.
command succeeded.
M40GBP$ set_en_act_hb_restore off
command succeeded.
M40GBP$ get_en_act_hb_restore
restore active state: off.
command succeeded.
M40GBP$