USER GUIDE
EdgeSafe 40G Bypass Modular Network TAP | M40GBP
Version 1.6 Page 118 of 159
Garland Technology reserves the right to make changes without further notice to any products or data herein to improve reliability, function or design.
Confidential -This document is
Garland Technology
.'s property. This document may not be copied, duplicated and transferred to electronic or mechanized
media or used for any other purpose, including any part thereof or attachment thereto, except as authorized in advance and in writing by
Garland Technology.
7.6 Bypass page
7.6.1 Bypass configuration area description
7.6.1.1
Heartbeat active mode select box
When heartbeat active mode is ON the M40GBP send heartbeat packets on its monitor ports. If the
M40GBP does not detect the heartbeat packet received from the monitor ports the M40GBP will switch
to
Active Bypass
or
TAP, TAPI12, TAPA, TAPAI1, TAPAI2, TAPAI12
or
Linkdrop
mode
according to the predefined settings of the HB active expire select box.
When heartbeat active mode is set to OFF the M40GBP stops sending the heartbeats and the Active
Bypass circuitry can be set manually via the management port to one of the following modes
Normal
(Inline), Active Bypass, TAP, TAPI12, TAPA, TAPAI1, TAPAI2, TAPAI12
or
Linkdrop
.
7.6.1.2
Heartbeat active mode lock select box
When HB active mode lock is ON the state of heartbeat active mode preserve after reboot or after
power on events. When HB active mode lock is OFF the state of heartbeat active mode is automatically
set to ON after reboot or after power on.