80
Parameter
Description
Read-only
Username
Set the read-only username accessing device, and it is
public
by
default.
You can enter number, letter, and underline to form the name.
Read/Write
Username
Set the read/write username access device, and it is
public
by
default.
You can enter number, letter, and underline to form the name.
Authentication Type
You can select from
MD5
and
SHA
. The default type is
MD5
.
Authentication
Password
It should be no less than 8 digits.
Encryption Type
The default is CBC-DES.
Encryption
Password
It should be no less than 8 digits.
Step 3 Click
Save
.
Verification
View device configuration through MIB Builder or MG-SOFT MIB Browser.
Step 1 Run MIB Builder and MG-SOFT MIB Browser.
Step 2 Compile the two MIB files with MIB Builder.
Step 3 Load the generated modules with MG-SOFT MIB Browser.
Step 4 Enter the IP address of the device you need to manage in the MG-SOFT MIB Browser,
and then select version to search.
Step 5 Unfold all the tree lists displayed in the MG-SOFT MIB Browser, and then you can view
the configuration information, video channel amount, audio channel amount, and
software version.
Use PC with Windows OS and disable SNMP Trap service. The MG-SOFT MIB Browser will
display prompt when alarm is triggered.
4.6.8 Bonjour
Enable this function, and the OS and clients that support Bonjour would find the camera
automatically. You can have quick visit to the camera with Safari browser.
Bonjour is enabled by default.