6.3 Peripheral Equipment
6-9
Chap. 6
SEL
ECT
ING P
E
R
IP
HE
RAL
EQ
UIPM
ENT
Table 6.5 Rated Current of Molded Case Circuit Breaker/Earth Leakage Circuit Breaker
and Magnetic Contactor
w/ DCR
w/o DCR
w/ DCR
w/o DCR
0.1
FRN0.1C1
-2
0.2
FRN0.2C1
-2
5 (6)
0.4
FRN0.4C1
-2
0.75
FRN0.75C1
-2
10
SC-05
SC-05
1.5
FRN1.5C1
-2
15 (16)
2.2
FRN2.2C1
-2
20 (25)
3.7, 4.0 FRN3.7C1
-2
20 (25)
30 (35)
SC-5-1
0.4
FRN0.4C1
-4
0.75
FRN0.75C1
-4
1.5
FRN1.5C1
-4
10
SC-05
SC-05
SC-05
2.2
FRN2.2C1
-4
15 (16)
3.7
4.0
FRN3.7C1
-4
FRN4.0C1
-4
10
20 (25)
0.1
FRN0.1C1
-7
0.2
FRN0.2C1
-7
5 (6)
0.4
FRN0.4C1
-7
10
SC-05
0.75
FRN0.75C1
-7
10
15 (16)
1.5
FRN1.5C1
-7
15 (16)
20 (25)
2.2
FRN2.2C1
-7
20 (25)
30 (35)
SC-5-1
Magnetic contactor type
MC2 (for output circuit)
Applicable
motor
rating
(kW)
MCCB, ELCB
Rated current (A)
Magnetic contactor type
MC1 (for input circuit)
DC reactor (DCR)
Inverter type
DC reactor (DCR)
Power
supply
voltage
Three-
phase
200 V
Three-
phase
400 V
Single-
phase
200 V
SC-05
SC-05
SC-05
5 (6)
10
5 (6)
5 (6)
5 (6)
- The above table lists the rated current of MCCBs and ELCBs to be used in the power control cabinet
with an internal temperature of lower than 50
°
C. The rated current is factored by a correction
coefficient of 0.85 as the MCCBs' and ELCBs' original rated current is specified when using them in
an ambient temperature of 40
°
C or lower. Select an MCCB and/or ELCB suitable for the actual
circuit breaking capacity needed for your power systems.
- For the selection of the MC, it is assumed that the
600V class of HIV (allowable ambient
temperature: 75
°°°°
C)
wires for the power input of the inverter are used. If an MC for another
class of wires is selected, the wire size suitable for the terminal size of both the inverter and MC
should be taken into account.
- ELCBs exclusively designed for protection from ground faults should not be used.
- To protect your power systems from secondary disasters caused by the broken inverter, use an MCCB
and/or ELCB with the rated current listed in the above table. Do not use an MCCB or ELCB with a
rating higher than that listed.
Notes: 1) A box (
) in the above table replace S or E depending on enclosure.
2) A box (
) in the above table replaces A, E, or J depending on shipping destination.
3) Values in parentheses ( ) in the above table denote rated currents for the European version.
Содержание frenic mini series
Страница 1: ...USER S MANUAL Fuji Electric Co Ltd MEH446...
Страница 2: ...Compact Inverter User s Manual...
Страница 60: ...4 2 4 2 Drive Frequency Command Generator Figure 4 1 Block Diagram for Drive Frequency Command Generator...
Страница 62: ...4 4 4 3 Drive Command Generator Figure 4 2 Drive Command Generator...
Страница 66: ...4 8 Figure 4 3 d Terminal Command Decoder ORing with Link Commands Ignoring Link Commands...
Страница 68: ...4 10 4 5 Digital Output Selector Figure 4 4 Digital Output Signal Selector...
Страница 70: ...4 12 4 6 Analog Output FMA Selector Figure 4 5 Analog Output FMA Selector...
Страница 72: ...4 14 4 7 Drive Command Controller Figure 4 6 Drive Command Controller and Related Part of the Inverter...
Страница 74: ...4 16 4 8 PID Frequency Command Generator Figure 4 7 PID Frequency Command Generator...
Страница 81: ...Part 3 Peripheral Equipment and Options Chapter 6 SELECTING PERIPHERAL EQUIPMENT...
Страница 109: ...Part 4 Selecting Optimal Inverter Model Chapter 7 SELECTING OPTIMAL MOTOR AND INVERTER CAPACITIES...
Страница 124: ...Part 5 Specifications Chapter 8 SPECIFICATIONS Chapter 9 FUNCTION CODES...
Страница 134: ...8 3 Common Specifications 8 9 Chap 8 SPECIFICATIONS 8 3 Common Specifications...
Страница 135: ...8 10...
Страница 257: ...App H Replacement Information A 33 App FVR C11S vs FRENIC Mini...
Страница 261: ...Glossary This glossary explains the technical terms that are frequently used in this manual...