![Fuji Electric frenic mini series Скачать руководство пользователя страница 160](http://html1.mh-extra.com/html/fuji-electric/frenic-mini-series/frenic-mini-series_user-manual_2341845160.webp)
9.1 Function Code Tables
9-3
Chap. 9
FUNCTI
ON C
O
DE
S
Code
Name
Data setting range
Incre-
mental
unit
Unit
Change
when
running
Data
copy
Default
setting
F12
(Thermal time constant) 0.5 to 75.0
0.1
min
Y
Y
5.0
F14 Restart Mode after
Instantaneous Power
Failure
0: Inactive (Trip immediately without restart)
1: Inactive (Trip without restart after recovery
of power)
4: Active (Restart at the frequency at which
the power failure occurred, for general
load)
5: Active (Restart at the starting frequency, for
low-inertia load)
—
—
Y
Y
1
(0)*
1
F15 Frequency Limiter
(Peak)
0.0 to 400.0
0.1
Hz
Y
Y
70.0
F16
(Bottom) 0.0 to 400.0
0.1
Hz
Y
Y
0.0
F18 Bias (for Frequency
Command 1)
-100.00 to 100.00
0.01
%
Y*
Y
0.00
F20 DC Braking
(Starting frequency)
0.0 to 60.0
0.1
Hz
Y
Y
0.0
F21
(Braking level) 0 to 100 (Rated output current of the inverter
interpreted as 100 %.)
1
%
Y
Y
0
F22
(Braking time) 0.00 (Disabled), 0.01 to 30.00
0.01 sec
Y
Y
0.00
F23 Starting Frequency
0.1 to 60.0
0.1
Hz
Y
Y
1.0
F25 Stop Frequency
0.1 to 60.0
0.1
Hz
Y
Y
0.2
F26 Motor Sound
(Carrier frequency)
0.75 to 15
1
kHz
Y
Y
2
(15)*
1
F27
(Sound tone) 0:
Level 0
1:
Level 1
2:
Level 2
3:
Level 3
—
—
Y
Y
0
F30 Terminal [FMA]
(Gain to output voltage)
0 to 200
If 100 is set, 10 VDC will be output from [FMA]
at full scale.
1
%
Y*
Y
100
F31 Analog Output Signal
Selection for [FMA]
(Monitor object)
0:
Output frequency 1
(before slip compensation)
Maximum output frequency at full scale
1:
Output frequency 2
(after slip compensation)
Maximum output frequency at full scale
2:
Output current
Two times the inverter's rated output
current at full scale
3:
Output voltage
250 V (500 V) at full scale
6:
Input power
Two times the inverter's rated output
capacity at full scale
7:
PID feedback amount
Feedback amount is 100 % at full scale
9:
DC link circuit voltage
500 VDC (1000 VDC) at full scale
14: Test analog output (+)
Full scale
—
—
Y
Y
0
*
1
Values in parentheses ( ) in the above table denote default settings for the European version except three-phase 200 V model.
Содержание frenic mini series
Страница 1: ...USER S MANUAL Fuji Electric Co Ltd MEH446...
Страница 2: ...Compact Inverter User s Manual...
Страница 60: ...4 2 4 2 Drive Frequency Command Generator Figure 4 1 Block Diagram for Drive Frequency Command Generator...
Страница 62: ...4 4 4 3 Drive Command Generator Figure 4 2 Drive Command Generator...
Страница 66: ...4 8 Figure 4 3 d Terminal Command Decoder ORing with Link Commands Ignoring Link Commands...
Страница 68: ...4 10 4 5 Digital Output Selector Figure 4 4 Digital Output Signal Selector...
Страница 70: ...4 12 4 6 Analog Output FMA Selector Figure 4 5 Analog Output FMA Selector...
Страница 72: ...4 14 4 7 Drive Command Controller Figure 4 6 Drive Command Controller and Related Part of the Inverter...
Страница 74: ...4 16 4 8 PID Frequency Command Generator Figure 4 7 PID Frequency Command Generator...
Страница 81: ...Part 3 Peripheral Equipment and Options Chapter 6 SELECTING PERIPHERAL EQUIPMENT...
Страница 109: ...Part 4 Selecting Optimal Inverter Model Chapter 7 SELECTING OPTIMAL MOTOR AND INVERTER CAPACITIES...
Страница 124: ...Part 5 Specifications Chapter 8 SPECIFICATIONS Chapter 9 FUNCTION CODES...
Страница 134: ...8 3 Common Specifications 8 9 Chap 8 SPECIFICATIONS 8 3 Common Specifications...
Страница 135: ...8 10...
Страница 257: ...App H Replacement Information A 33 App FVR C11S vs FRENIC Mini...
Страница 261: ...Glossary This glossary explains the technical terms that are frequently used in this manual...