![Fuji Electric frenic mini series Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/fuji-electric/frenic-mini-series/frenic-mini-series_user-manual_2341845045.webp)
3-14
3.3.3 Monitoring the Running Status--"Drive monitoring"
Menu #3 "Drive monitoring" is used to check the running status during maintenance and test
running. The display items for "Drive monitoring" are listed in Table 3.5. Using keys, you may
check those items in succession. Figure 3.7 shows the status transition diagram for "Drive
monitoring."
Table 3.5 Drive Monitoring Display Items
LED monitor
shows:
Contents
Unit
Description
3_00
Output
frequency
Hz
Output frequency before slip compensation
3_01
Output
frequency
Hz
Output frequency after slip compensation
3_02
Output
current
A
Present output current
3_03
Output
voltage
V
Present output voltage
3_05
Set frequency
Hz
Present set frequency
3_06
Running
direction
N/A
Displays the running direction currently being outputted.
F
: forward;
R
: reverse,
– – – –
: stop
3_07
Running
status
N/A
Displays the running status in hex. format. Refer to
"Displaying running status" on the next page.
3_09
Load shaft
speed
(line speed)
rpm
(m/min)
The unit for load shaft speed is rpm and that for line speed
is m/min.
Display value = (Output frequency Hz before slip
compensation)
×
(Function code E50)
is displayed for 10000 (rpm or m/min) or more.
When
is displayed, the data is overflowing, which
means that the function code should be reviewed. For
example:
Load shaft speed = Displayed data
×
10 (rpm)
3_10
PID process
commands
N/A
These commands are displayed through the use of function
code E40 and E41 (PID display coefficient A and B).
Display value = (PID process command)
×
(
PID display
coefficient
A - B) + B
If PID control is disabled, "
– – – –
" appears.
3_11
PID feedback
amount
N/A
This value is displayed through the use of function code
E40 and function code E41 (PID display coefficient A and
B).
Display value = (PID feedback amount)
×
(
PID display
coefficient
A - B) + B
If PID control is disabled, "
– – – –
" appears.
Содержание frenic mini series
Страница 1: ...USER S MANUAL Fuji Electric Co Ltd MEH446...
Страница 2: ...Compact Inverter User s Manual...
Страница 60: ...4 2 4 2 Drive Frequency Command Generator Figure 4 1 Block Diagram for Drive Frequency Command Generator...
Страница 62: ...4 4 4 3 Drive Command Generator Figure 4 2 Drive Command Generator...
Страница 66: ...4 8 Figure 4 3 d Terminal Command Decoder ORing with Link Commands Ignoring Link Commands...
Страница 68: ...4 10 4 5 Digital Output Selector Figure 4 4 Digital Output Signal Selector...
Страница 70: ...4 12 4 6 Analog Output FMA Selector Figure 4 5 Analog Output FMA Selector...
Страница 72: ...4 14 4 7 Drive Command Controller Figure 4 6 Drive Command Controller and Related Part of the Inverter...
Страница 74: ...4 16 4 8 PID Frequency Command Generator Figure 4 7 PID Frequency Command Generator...
Страница 81: ...Part 3 Peripheral Equipment and Options Chapter 6 SELECTING PERIPHERAL EQUIPMENT...
Страница 109: ...Part 4 Selecting Optimal Inverter Model Chapter 7 SELECTING OPTIMAL MOTOR AND INVERTER CAPACITIES...
Страница 124: ...Part 5 Specifications Chapter 8 SPECIFICATIONS Chapter 9 FUNCTION CODES...
Страница 134: ...8 3 Common Specifications 8 9 Chap 8 SPECIFICATIONS 8 3 Common Specifications...
Страница 135: ...8 10...
Страница 257: ...App H Replacement Information A 33 App FVR C11S vs FRENIC Mini...
Страница 261: ...Glossary This glossary explains the technical terms that are frequently used in this manual...