![Fuji Electric frenic mini series Скачать руководство пользователя страница 196](http://html1.mh-extra.com/html/fuji-electric/frenic-mini-series/frenic-mini-series_user-manual_2341845196.webp)
9.2 Details of Function Codes
9-39
Chap. 9
FUNCTI
ON C
O
DE
S
E48
LED Monitor (Speed monitor item)
If E48 is
set to:
The LED monitor displays the
sub item:
0
Output frequency before slip
compensation
1
Output frequency after slip
compensation
2
Set frequency
4
Load shaft speed in rpm
5
Line speed in m/min
Selects the speed-monitoring format on
the LED monitor.
6
Constant feeding rate time
E50
Coefficient for Speed Indication
Refer to E39.
Detail for the speed display coefficient setting is given in the description of function code
E39.
E52
Menu Display Mode for Keypad
Selects the menu display mode for the keypad in Programming mode.
If E52 is set to:
The keypad will enter:
0
Function code data setting mode in which Menu #1 "Data setting" only is
displayed.
1
Function code data check mode in which Menu #2 "Data checking" only is
displayed.
2
Full-menu mode in which all menus may be displayed.
E60
Built-in Potentiometer (Function selection)
E61
Analog Input Signal Definition for [12]
E62
Analog Input Signal Definition for [C1]
E60, E61, and E62 define the function of the built-in potentiometer, terminals [12] and
[C1], respectively.
If E60, E61, or E62
is set to:
This function will be defined
for potentiometer and terminals [12] and [C1]:
0
None
1
Auxiliary frequency command 1*
2
Auxiliary frequency command 2**
3
PID process command 1 (J02 setting is also required.)
5
PID feedback value (Not applicable to function code E60)
* This is an auxiliary frequency input to be added to frequency command 1, but never to frequency command 2.
Frequency commands 1 and 2 are frequencies set by the means specified by F01 and C30, respectively. The set
frequency can be switched between, for example, frequency command 1 added by the auxiliary frequency and the
raw frequency 2 added by nothing, to drive the motor in the desired manner. For more details, refer to Chapter 4,
Section 4.2 "Drive Frequency Command Generator."
** An auxiliary frequency input to be added to the set frequency. For example, the auxiliary frequency input to be added
to the preset frequency used for the multi-step frequency operation.
If the same data is set to these function codes, the priority order will be:
E60 > E61 > E62
Содержание frenic mini series
Страница 1: ...USER S MANUAL Fuji Electric Co Ltd MEH446...
Страница 2: ...Compact Inverter User s Manual...
Страница 60: ...4 2 4 2 Drive Frequency Command Generator Figure 4 1 Block Diagram for Drive Frequency Command Generator...
Страница 62: ...4 4 4 3 Drive Command Generator Figure 4 2 Drive Command Generator...
Страница 66: ...4 8 Figure 4 3 d Terminal Command Decoder ORing with Link Commands Ignoring Link Commands...
Страница 68: ...4 10 4 5 Digital Output Selector Figure 4 4 Digital Output Signal Selector...
Страница 70: ...4 12 4 6 Analog Output FMA Selector Figure 4 5 Analog Output FMA Selector...
Страница 72: ...4 14 4 7 Drive Command Controller Figure 4 6 Drive Command Controller and Related Part of the Inverter...
Страница 74: ...4 16 4 8 PID Frequency Command Generator Figure 4 7 PID Frequency Command Generator...
Страница 81: ...Part 3 Peripheral Equipment and Options Chapter 6 SELECTING PERIPHERAL EQUIPMENT...
Страница 109: ...Part 4 Selecting Optimal Inverter Model Chapter 7 SELECTING OPTIMAL MOTOR AND INVERTER CAPACITIES...
Страница 124: ...Part 5 Specifications Chapter 8 SPECIFICATIONS Chapter 9 FUNCTION CODES...
Страница 134: ...8 3 Common Specifications 8 9 Chap 8 SPECIFICATIONS 8 3 Common Specifications...
Страница 135: ...8 10...
Страница 257: ...App H Replacement Information A 33 App FVR C11S vs FRENIC Mini...
Страница 261: ...Glossary This glossary explains the technical terms that are frequently used in this manual...