![Fuji Electric frenic mini series Скачать руководство пользователя страница 116](http://html1.mh-extra.com/html/fuji-electric/frenic-mini-series/frenic-mini-series_user-manual_2341845116.webp)
7-6
(3)
Deceleration time (For detailed calculation, refer to Section 7.1.3.2)
To calculate the deceleration time, check the motor deceleration torque characteristics for the
whole range of speed in the same way as for the acceleration time.
1) Calculate the moment of inertia for the load and motor
Same as for the acceleration time.
2) Calculate the minimum deceleration torque (See Figures 7.5 and 7.6.)
Same as for the acceleration time.
3) Calculate the deceleration time
Assign the value calculated above to the equation (7.11) to calculate the deceleration time
in the same way as for the acceleration time. If the calculated deceleration time is longer
than the requested time, select the inverter and motor having one class larger capacity and
calculate it again.
Figure 7.5
Example Study of Minimum
Deceleration Torque (1)
Figure 7.6
Example Study of Minimum
Deceleration Torque (2)
(4)
Braking resistor rating (For detailed calculation, refer to Section 7.1.3.3)
Braking resistor rating is classified into two types according to the braking periodic duty cycle.
1) When the periodic duty cycle is shorter than 100 sec:
Calculate the average loss to determine rated values.
2) When the periodic duty cycle is 100 sec or longer:
The allowable braking energy depends on the maximum regenerative braking power. The
allowable values are listed in Chapter 6, Section 6.4.1 [1] "Braking Resistor."
(5)
Motor RMS current (For detailed calculation, refer to Section 7.1.3.4)
In metal processing machine and materials handling machines requiring positioning control,
highly frequent running for a short time is repeated. In this case, calculate the maximum
equivalent RMS current value (effective value of current) not to exceed the allowable value
(rated current) for the motor.
Содержание frenic mini series
Страница 1: ...USER S MANUAL Fuji Electric Co Ltd MEH446...
Страница 2: ...Compact Inverter User s Manual...
Страница 60: ...4 2 4 2 Drive Frequency Command Generator Figure 4 1 Block Diagram for Drive Frequency Command Generator...
Страница 62: ...4 4 4 3 Drive Command Generator Figure 4 2 Drive Command Generator...
Страница 66: ...4 8 Figure 4 3 d Terminal Command Decoder ORing with Link Commands Ignoring Link Commands...
Страница 68: ...4 10 4 5 Digital Output Selector Figure 4 4 Digital Output Signal Selector...
Страница 70: ...4 12 4 6 Analog Output FMA Selector Figure 4 5 Analog Output FMA Selector...
Страница 72: ...4 14 4 7 Drive Command Controller Figure 4 6 Drive Command Controller and Related Part of the Inverter...
Страница 74: ...4 16 4 8 PID Frequency Command Generator Figure 4 7 PID Frequency Command Generator...
Страница 81: ...Part 3 Peripheral Equipment and Options Chapter 6 SELECTING PERIPHERAL EQUIPMENT...
Страница 109: ...Part 4 Selecting Optimal Inverter Model Chapter 7 SELECTING OPTIMAL MOTOR AND INVERTER CAPACITIES...
Страница 124: ...Part 5 Specifications Chapter 8 SPECIFICATIONS Chapter 9 FUNCTION CODES...
Страница 134: ...8 3 Common Specifications 8 9 Chap 8 SPECIFICATIONS 8 3 Common Specifications...
Страница 135: ...8 10...
Страница 257: ...App H Replacement Information A 33 App FVR C11S vs FRENIC Mini...
Страница 261: ...Glossary This glossary explains the technical terms that are frequently used in this manual...