![Fuji Electric frenic mini series Скачать руководство пользователя страница 165](http://html1.mh-extra.com/html/fuji-electric/frenic-mini-series/frenic-mini-series_user-manual_2341845165.webp)
9-8
P codes: Motor Parameters
Code
Name
Data setting range
Incre-
mental
unit
Unit
Change
when
running
Data
copy
Default
setting
P02 Motor Parameters
(Rated capacity)
0.01 to 10.00 kW (where, the data of function
code P99 is 0, 3, or 4.)
0.01 to 10.00 HP (where, the data of function
code P99 is 1.)
0.01
0.01
kW
HP
N
Y
Nominal *
rated
capacity
of Fuji's
standard
motor
P03
(Rated current) 0.00 to 99.99
0.01
A
N
Y1
Y2
Nominal *
rated
current of
Fuji's
standard
motor
P09
(Slip compensation
gain)
0.0 to 200.0
Typical rated slip frequency
at 100%
0.1
%
Y*
Y
0.0
P99 Motor Selection
0: Characteristics of motor 0
(Fuji's standard 8-series motors)
1: Characteristics of motor 1 (HP motors)
3: Characteristics of motor 3
(Fuji's standard 6-series motors)
4: Other motors
—
—
N
Y
0
H codes: High Performance Functions
Code
Name
Data setting range
Incre-
mental
unit
Unit
Change
when
running
Data
copy
Default
setting
H03 Data Initialization
(Data reset)
0: Disable initialization
1: Initialize all function code data to the factory
defaults
2: Initialize motor parameters
—
—
N
N
0
H04 Retry
(No. of retries)
0: Inactive
1 to 10
1
Times
Y
Y
0
H05
(Latency time) 0.5 to 20.0
0.1
sec
Y
Y
5.0
H06 Cooling Fan ON/OFF
0: Inactive
1: Active (1.5 kW or more)
—
—
Y
Y
0
H07 Gradual Acceleration/
Deceleration
0: Inactive (Linear)
1: S-curve (Weak)
2: S-curve (Strong)
3: Curvilinear
—
—
Y
Y
0
H12 Instantaneous
Overcurrent Limiting
0: Inactive (OC trip at current limiting level by
hardware detection)
1: Active (Turning gates OFF immediately at
current limiting level by hardware
detection)
—
—
Y
Y
1
H26 PTC Thermistor Input
0: Inactive
1: Active (PTC)
—
—
Y
Y
0
H27
(Level) 0.00 to 5.00
0.01
V
Y
Y
1.60
H30 Serial Link
(Function selection)
Monitor Frequency command
Run command
0:
Y
N
N
1:
Y
RS485
N
2:
Y
N
RS485
3:
Y
RS485
RS485
Y:
Enable by inverter and RS485
RS485:
Enable by RS485
N:
Enable by inverter
—
—
Y
Y
0
H42 Capacity of DC bus
capacitor
For adjustment when replacing the capacitor
—
—
—
N
—
H43 Accumulated Run
Time of Cooling Fan
For adjustment when replacing the cooling fan
—
—
—
N
—
*The "Fuji's standard torque boost," "Nominal rated current of Fuji's standard motor," and "Nominal rated capacity of Fuji's
standard motor" differ depending upon the rated input voltage and rated capacity. Refer to page 9-10.
Содержание frenic mini series
Страница 1: ...USER S MANUAL Fuji Electric Co Ltd MEH446...
Страница 2: ...Compact Inverter User s Manual...
Страница 60: ...4 2 4 2 Drive Frequency Command Generator Figure 4 1 Block Diagram for Drive Frequency Command Generator...
Страница 62: ...4 4 4 3 Drive Command Generator Figure 4 2 Drive Command Generator...
Страница 66: ...4 8 Figure 4 3 d Terminal Command Decoder ORing with Link Commands Ignoring Link Commands...
Страница 68: ...4 10 4 5 Digital Output Selector Figure 4 4 Digital Output Signal Selector...
Страница 70: ...4 12 4 6 Analog Output FMA Selector Figure 4 5 Analog Output FMA Selector...
Страница 72: ...4 14 4 7 Drive Command Controller Figure 4 6 Drive Command Controller and Related Part of the Inverter...
Страница 74: ...4 16 4 8 PID Frequency Command Generator Figure 4 7 PID Frequency Command Generator...
Страница 81: ...Part 3 Peripheral Equipment and Options Chapter 6 SELECTING PERIPHERAL EQUIPMENT...
Страница 109: ...Part 4 Selecting Optimal Inverter Model Chapter 7 SELECTING OPTIMAL MOTOR AND INVERTER CAPACITIES...
Страница 124: ...Part 5 Specifications Chapter 8 SPECIFICATIONS Chapter 9 FUNCTION CODES...
Страница 134: ...8 3 Common Specifications 8 9 Chap 8 SPECIFICATIONS 8 3 Common Specifications...
Страница 135: ...8 10...
Страница 257: ...App H Replacement Information A 33 App FVR C11S vs FRENIC Mini...