4.6 Electrical connection
DANGER
When working on electrical components:
Risk of electrocution!
When work is carried out on electrical components:
❒ Only have work carried out by a qualified electrician
❒ Observe the applicable standards and regulations
➥ Work must not be carried out on electrical components by unauthorised
people
❒ Lay cables of all components to the switch cabinet
❒ Connect cables in the switch cabinet according to the wiring diagram
➥ For connection see corresponding documentation for firewood boiler
❒ Secure cables to the strain relief bar with cable ties
Notes on laying cables
▪ The cables of the individual units may have excess length. These cables should
be coiled in the cable duct.
▪ Spread the coils of excess cable over the entire cable ducts to prevent the cable
ducts from being overfilled!
▪ Bind the freely hanging cable to the drive motors using cable ties. The cables must
not come into contact with the stoker duct!
4.6.1 Installing insulating covers and cover plates
After wiring the components all cover plates and insulating covers must be installed:
❒ Mount cable ducts at the designated positions on the insulating side panels
❒ Mount cover plate of vertical cable duct on the back side of the boiler
Assembly
4
Electrical connection
Installation Instructions TX 150-250 | M1320112_en
61