❒ Place the safety limit switch so that the key plate can easily be threaded to the
switch
❒ Fix the position of the safety limit switch by fastening the screwings at the angle
plat and limit switch
❒ Mount the gear motor with 4 hexagonal bolts on the flange plate
❒ Put the ash screw onto the back side of the boiler
❒ Dismount the shaft circlip (big hexagonal bolt and lining disk) and the key at the
end of the shaft
❒ Put the ceramic fibre seal and the gear motor onto the screw
❒ Slide the shaft entirely into the gear drive and rotate it until the key at the shaft
aligns with the key at the gear drive, afterwards insert the fitting key