❒ Put the actuator together with the torque arm on the right grate shaft
❒ Fix the torque arm with 2 round-head screws M8x20, lining disks M8 and lock nuts
M8 at the fire box
❒ Fix the sensor mounting at the side of the left grate shaft with 2 round-head
screws M8x20, lining disks M8 and lock nuts M8 at the fire box
❒ Thread the proximity sensor at the mounting and fix it easily with pre-installed nuts
❒ Fix the sensor with approx. 1-2 mm (0.04-0.08 inch) separation
❒ Lay the connection cable of the sensor and the actuator on the left side upwards
and lead it through the upper opening at the frame element
4
Assembly
Mounting steps