❒ Position the cover plate at the combustion chamber door and fix it on the left and
on the right with thread forming screws
❒ Mount safety limit switch at the frame element
❒ Loosen screwings at the key plate
❒ Close the combustion chamber door and adjust the key plate so that an unproble‐
matic locking at the safety limit switch is possible
❒ Fix the positioning of the key plate and check the correct locking at the limit switch
when opening and closing the combustion chamber door for several times
❒ Lay the connection cable of the safety limit switch upwards through the upper
opening of the frame element
4
Assembly
Mounting steps
30