❒ Thread the cable of the safety limit switch through both cuttings at the frame ele‐
ment, lay them on the left side upwards and thread them through at the upper
opening of the frame element
❒ Put two heat insulation mats on the ash flange
❒ Fix the cover plates on the left and the right of the ash removal flange with thread
forming screws
❒ Insert the protection plate above the leverage of the tipping device and fix it with
thread forming screws at the fire box
❒ Put the ash box onto the ash removal flange and lock it
Assembly