ELECTRICAL WIRING
31 March, 1999
6-38
6.5.3 HIGH VOLTAGE SUPPLY UNIT
1. Remove the right cover (see Right Cover Removal), left cover (see Left Cover
Removal), controller board (see Controller Board Removal), and power supply
unit (see Power Supply Unit Removal).
2. Open the rear side panel [A] (eight screws and two hooks).
NOTE: Before opening the rear side panel, unplug connectors from the power
supply unit and the high-voltage supply unit as necessary.
3. Remove the high-voltage supply unit [B] (four screws, two hooks, eight
connectors).
ø
CAUTION
Carefully connect the high-voltage wires as shown in the diagram below.
G024R255.WMF
C N 1 9 0
G024R512.WMF
White connector:
Belt transfer bias
roller
Yellow connector:
Development blade
White connector:
Development roller
Blue connector:
Supply roller
Yellow connector:
Charge corona unit
wire
Blue connector:
Charge corona unit grid
White connector:
Transfer roller
[A]
[B]
Содержание G024