5100ex Calibration Manual
Description of Calibration Values
15
Prewet
The Prewet menu allows you to configure settings for the vehicle's prewet liquid output. These
settings are not particular to any prewet material. None of the settings in this menu have any
effect if Prewet is disabled in the System menu. If Config → Application Mode is set to Direct 1
Lane or Direct 3 Lane or if Config → Prewet is disabled, this menu will be disabled.
Options
The Options submenu allows you to set the Loop Mode, Gain, Manual Mode, Prewet
Prime, and Drive Type for the vehicle’s prewet output.
Loop Mode
The Loop Mode menu item sets the prewet output into Closed Loop, Open Loop,
Manual Mode, or Gravity Feed. The default value is Open Loop Mode.
Gain
The Gain menu item is a multiplier applied to closed loop prewet operation, used
to fine-tune the prewet system’s sensitivity to changes in vehicle speed or prewet
set rate. A high gain value will cause the prewet system to adapt to changes
quickly but might cause the system to overshoot the target RPM. A low gain
value will cause the prewet system to adapt to changes slowly but might cause
the system to under apply material until it reaches the target RPM. The default
value is 250. The Gain menu item will not be available if the Loop Mode menu
item is set to Open, Manual, or Gravity Feed.
If the prewet pump is hunting and not settling at a steady speed, try reducing the
Gain value.
Manual Mode
The Manual Mode menu item enables or disables the driver-accessible Prewet
Manual mode item in the Materials Menu. When operated in Manual mode, the
5100ex ignores any connected prewet feedback sensor and vehicle ground
speed and will instead drive the prewet output at a fixed percent of maximum
speed. The default value is disabled. The Manual Mode menu item will not be
available if the Loop Mode menu item is set to Manual or Gravity Feed.
Low Prewet
The Low Prewet menu item determines what spreader action is triggered when
the Prewet Low input becomes active. The available options are Warn or Warn +
Disable. The default value is Warn.
Function
Operation
Warn
Prewet low liquid error will appear in the header bar.
Warn + Disable
Prewet low liquid error will appear in the header bar and the
prewet output will be turned off. The output will be
prevented from turning on as long as the prewet low liquid
input is active.
Prewet Prime
The Prewet Prime menu item enables prewet prime mode for the prewet material
in the Unload/Prime menu. The default value is disabled.
Drive Type
The Drive Type menu item sets the drive type of the prewet system. The
available options are Hydraulic, Electric, and Exhaust. The default value is
Hydraulic.