5100ex Calibration Manual
AutoCalibration of Direct Liquid
42
AutoCalibration of a Direct Liquid
The 5100ex can automatically calculate the displacement and full speed displacement rate values
by dispensing direct liquid. Before you begin, make sure Direct Min DC and Max DC have been
calibrated.
To auto calibrate a direct liquid:
Calibrating displacement and full speed displacement rate can be completed using either English
or Metric units. The steps below will walk you through calibrating the displacement and full speed
displacement rate using English units.
STEP 1:
Enter the Calibration Menu. See Entering the Calibration Menu on page 2.
STEP 2:
Select a Direct Liquid type to calibrate: Anti-Ice, Dust Control, or Herbicide
STEP 3:
Select AutoCal.
STEP 4:
The Direct AutoCal screen will appear, as shown in Figure 10.
Figure 10: Direct AutoCal Screen
STEP 5:
Press the Continue button to dismiss the dialog.
STEP 6:
Setup a catch container under the direct system to catch any liquid that is
dispensed.
STEP 7:
Set the direct percent by twisting the green knob. The value must be greater
than 40% and cannot be adjusted once the process is started.
STEP 8:
If Config → Application Mode is set to Gran/Dir 3 Lane or Direct 3 Lane, the left,
center, and right lanes can be turned on an off using the first three switches.
STEP 9:
Press the green, Standby knob to begin dispensing material. The status should
change to “running”.
STEP 10: Wait until at least 2 gallons of liquid have been dispensed. The more material
dispensed, the higher the accuracy of the calibration.