5100ex Calibration Manual
Description of Calibration Values
13
In the 5150 systems, the Parent can only be set to Disabled or Aug Fwd.
Min DC
The Min DC menu item sets the duty cycle required to turn the spinner at its
slowest rate. The default value is 20%. Min DC button is disabled when Spinner
1 Parent is Disabled and enabled for all other Parent options.
Use the green Standby knob to test the spinner speed when adjusting the Min
DC value.
Max DC
The Max DC menu item sets the duty cycle required to turn the spinner at its
fastest rate. The default value is 75%. Min DC button is disabled when Spinner 1
Parent is Disabled and enabled for all other Parent options.
Use the green Standby knob to test the spinner speed when adjusting the Max
DC value.
Spinner 2
The Spinner 2 submenu contains settings for Spinner 2, typically a secondary or alternate
direction spinner. None of the settings in this submenu have any effect if Spinner 1 or
Spinner 2 Parent is set to disabled. The Spinner 2 button and submenu are disabled in
the 5150ex systems or if Spinner 1 is disabled.
Parent
The Parent menu item sets when Spinner 2 will run. When the parent function is
running, the spinner will run. If Spinner 1 and Spinner 2 are both set to the same
Parent, both will run when that Parent is active. When in auger manual mode the
spinner will run based on the spinner setting when the system is not in Standby.
The default value is Disabled.
Parent
Operation
Disabled
Spinner 2 will not run.
Aug Fwd
Spinner 2 will run when Auger Forward output is active.
Aug Rev
Spinner 2 will run when Auger Reverse output is active.
Cross 1
Spinner 2 will run when Cross 1 output is active.
Cross 2
Spinner 2 will run when Cross 2 output is active.
Auger
Spinner 2 will run when either Auger Fwd or Rev is active.
If a vehicle is equipped with a reversing tailgate auger, reversible main conveyor,
or cross auger, the main direction spinner will be driven by the Spinner 1 output
and the alternate direction spinner will be driven by the Spinner 2 output.
In these cases, set the Spinner 1 → Parent value to the primary direction of the
associated auger or conveyor. Set the Spinner 2 → Parent value to the alternate
direction of the associated auger or conveyor.
Min DC
The Min DC menu item sets the duty cycle required to turn Spinner 2 at its
slowest rate. The default value is 20%. Min DC button is disabled when Spinner
2 Parent is Disabled and enabled for all other Parent options.
Use the green Standby knob to test the spinner speed when adjusting the Min
DC value.