5100ex Calibration Manual
Description of Calibration Values
19
If the direct pump is hunting and not settling at a steady speed, try reducing the
Gain value.
The Gain menu item will not be available if the Loop menu item is set to Open.
Blast Time
The Blast Time menu item sets the amount of time in seconds that blast will run
once the blue Blast Knob has been pressed and released. The default value is
10 seconds.
Manual Mode
The Manual Mode menu item enables or disables the Manual mode switch on
the Operation Screen. When operated in Manual mode, the 5100ex ignores any
connected direct feedback sensor and vehicle ground speed and will instead
drive the direct pump at a fixed percent of maximum speed. The default value is
disabled.
Unload
The Unload menu item enables unload mode for direct liquid in the Unload/Prime
menu. The default value is disabled.
Low Direct
The Low Direct menu item determines what spreader action is triggered when
the Low Direct input becomes active. The available options are Warn or Warn +
Disable. The default value is Warn.
Function
Operation
Warn
Low direct error will appear in the header bar.
Warn + Disable
Low direct error will appear in the header bar and the direct
output will be turned off. The output will be prevented from
turning on as long as the low direct input is active.
Output Connector
The Output Connector menu item determines what spreader output the direct
system will use. The available options are Aug Fwd and Cross Rt/Direct. The
default value is Cross Rt/Direct.
Min DC
The Min DC menu item sets the duty cycle required to run the direct pump at its slowest
rate. Min DC is used in closed, open, manual, and unload modes, and should be
configured as accurately as possible. The default value is 20%.
Use the green Standby knob to test the direct pump output when adjusting the Min DC
value. If the loop mode is set to Closed and a direct flowmeter is installed on the system,
the current direct flowmeter frequency will also be shown on the screen to assist with
adjustments.
If Config → Application Mode is set to Gran/Dir 3 Lane or Direct 3 Lane, the left, center,
and right lanes can be turned on an off using the first three switches.
Max DC
The Max DC menu item sets the duty cycle required to run the direct pump at its fastest
rate. Max DC is used in closed, open, manual, and unload modes, and should be
configured as accurately as possible. The default value is 75%.