5100ex Calibration Manual
Description of Calibration Values
10
Parent
The Parent menu item sets when the Cross Auger 2 will run. When the parent
function is running, the cross auger will run at a speed proportional to the speed
of its parent function. If the parent function for Cross 1 and Cross 2 are the
same, the active cross auger is determined using the CROSS LEFT/RIGHT soft
switch. Cross 1 will operate when LEFT is selected and Cross 2 will operate
when RIGHT is selected. The default value is Disabled.
Parent
Operation
Disabled
Cross 2 will not run.
Aug Fwd
Cross 2 will run when the auger forward output is active.
Aug Rev
Cross 2 will run when the auger reverse output is active.
Min DC
The Min DC menu item sets the duty cycle required to turn cross auger 2 at its
slowest rate. The default value is 20%. Min DC is enabled when Cross Auger 2
Parent is set to Aug Fwd or Aug Rev. Min DC is disabled when Cross Auger 2
Parent is Disabled.
Use the green Standby knob to test the cross auger speed when adjusting the
Min DC value.
Max DC
The Max DC menu item sets the duty cycle required to turn cross auger 2 at its
fastest rate. The default value is 75%. Max DC is enabled when Cross Auger 2
Parent is set to Aug Fwd or Aug Rev. Max DC is disabled when Cross Auger 2
Parent is Disabled.
Use the green Standby knob to test the cross auger speed when adjusting the
Max DC value.
Granular Mats
The Granular Materials menu allows you to configure settings for up to 4 individual granular
materials. These settings include custom displacement, set, and blast rates for each material. If
Config → Application Mode is set to Direct 1 Lane or Direct 3 Lane, this menu will be disabled.
Materials Enabled
The Materials Enabled menu item changes how many granular materials will be available
to the 5100ex during operation. If a granular material is configured with non-default
settings and then is disabled with this menu item, its custom settings will not be cleared.
The default value is 1.
Mat 1, Mat 2, Mat 3, etc.
Entering the Mat # submenu presents the custom settings available for a particular
granular material.
Name
The Name menu item allows you to set a custom name for the granular material,
such as “SAND” or “SALT”. A maximum of 5 characters can be used in the
material name. This name will appear on the Operation Screen when selected.
The default values are MAT1, MAT2, MAT3, and MAT4.