5100ex Calibration Manual
Description of Calibration Values
9
Max DC
The Max DC menu item sets the duty cycle required to turn the auger at its
fastest rate. Max DC is used in closed, open, manual, and unload modes when
Auger Reverse is active and should be configured as accurately as possible. The
default value is 75%.
Use the green Standby knob to test the auger speed when adjusting the Max DC
value. If a cross auger has its parent function set to Auger Reverse it will run at
max. If both cross augers have its parent function set to Auger Reverse, then
whichever was last selected on the operation screen will run at max (and the
other will stay off). The current Auger RPM will be shown on the screen to assist
with adjustments.
Cross 1
The Cross 1 submenu contains the Minimum and Maximum Duty Cycle settings for
running a single direction cross auger, or a dual-direction cross auger in the left direction.
If Config → Application Mode is set to Gran/Dir 1 Lane, Gran/Dir 3 Lane, Direct 1 Lane,
or Direct 3 Lane, this menu will be disabled. The Cross 1 button and submenu is also
disabled in 5150 systems.
Parent
The Parent menu item sets when the Cross Auger 1 will run. When the parent
function is running, the cross auger will run at a speed proportional to the speed
of its parent function. If the parent function for Cross 1 and Cross 2 are the
same, the active cross auger is determined using the CROSS LEFT/RIGHT soft
switch. Cross 1 will operate when LEFT is selected and Cross 2 will operate
when RIGHT is selected. The default value is Disabled.
Parent
Operation
Disabled
Cross 1 will not run.
Aug Fwd
Cross 1 will run when the auger forward output is active.
Aug Rev
Cross 1 will run when the auger reverse output is active.
Min DC
The Min DC menu item sets the duty cycle required to turn the cross auger at its
slowest rate. The default value is 20%. Min DC is enabled when Cross Auger 1
Parent is set to Aug Fwd or Aug Rev. Min DC is disabled when Cross Auger 1
Parent is Disabled.
Max DC
The Max DC menu item sets the duty cycle required to turn the cross auger at its
fastest rate. The default value is 75%. Max DC is enabled when Cross Auger 1
Parent is set to Aug Fwd or Aug Rev. Max DC is disabled when Cross Auger 1
Parent is Disabled.
Cross 2
The Cross Auger 2 submenu contains the Minimum and Maximum Duty Cycle settings
for running a second cross auger or dual-direction cross auger in the right direction. If
Config → Application Mode is set to Gran/Dir 1 Lane, Gran/Dir 3 Lane, Direct 1 Lane, or
Direct 3 Lane, this menu will be disabled. The Cross 2 button and submenu is also
disabled in 5150 systems or if Cross 1 is disabled.