5100ex Calibration Manual
AutoCalibration of Granular Materials
32
AutoCalibration of Granular Materials
The 5100ex can automatically calculate the displacement and full speed displacement rate values
by dispensing granular material. Before you begin make sure Auger Min DC and Max DC have
been calibrated. If your system uses a cross auger, also make sure Cross Min DC and Max DC
have been calibrated.
To auto calibrate a granular material:
Calibrating displacement and full speed displacement rate can be completed using either English
or Metric units. The steps below will walk you through calibrating the displacement and full speed
displacement rate using English units.
STEP 1:
Enter the Calibration Menu. See Entering the Calibration Menu on page 2.
STEP 2:
Select Granular Mats
STEP 3:
Select the Material you wish to calibrate.
STEP 4:
Select AutoCal.
STEP 5:
The Granular AutoCal screen will appear, as shown in Figure 4.
Figure 4: Granular AutoCal Screen
STEP 6:
Press the Continue button to dismiss the dialog.
STEP 7:
Setup a catch container under the auger to catch any material that is dispensed.
STEP 8:
Set the auger percent by twisting the green knob. The value must be greater
than 40% and cannot be adjusted once the process is started.
STEP 9:
Set the spinner percent to the desired value, if you are using spinner, by twisting
the blue knob.
STEP 10: Press the green, Standby knob to begin dispensing material. The status should
change to “Running”.
STEP 11: Wait until at least 25 pounds of material have been dispensed. The more
material dispensed, the higher the accuracy of the calibration.