5100ex Calibration Manual
Description of Calibration Values
18
Set Rate 1, Set Rate 2, Set Rate 3, etc.
The Set Rate menu item sets which gallons per ton or liters per ton setting will be
output when the user chooses the corresponding set rate. The default values are
shown in the table below.
Set Rate
Default English Rate
(Gallons per Ton)
Default Metric Rate
(Liters per Tonne)
Set Rate 1
3.0
12.5
Set Rate 2
4.0
16.7
Set Rate 3
5.0
20.9
Set Rate 4
6.0
25.0
Set Rate 5
7.0
29.2
Set Rate 6
8.0
33.4
Direct
The Direct menu allows you to configure settings for the vehicle's direct liquid output. These
settings are not particular to any direct material. None of the settings in this menu have any effect
if Application Mode is set to Granular in the System menu. If Config → Application Mode is set to
Granular, this menu will be disabled.
Options
The Options submenu allows you to set the Loop Mode, Gain, Blast Time, Manual Mode,
Unload, Low Liquid, and Output Connector for the vehicle’s direct output.
Direct Type
The Direct Type menu item sets the specific type or combinations of multiple
types of direct liquid application used by the controller. Each combination of the
three types: Anti-Ice, Dust Control, and Herbicide are available. The default
value is Anti-Ice.
The spreading units are chosen based on the selected Direct Type as follows:
Type
English Units
Metric Units
Anti-Ice
Gal/Mi
L/KM
Dust Control
Gal/Sq Yd
L/M
2
Herbicide
Gal/Ac
L/HA
Loop Mode
The Loop Mode menu item sets the direct output into either Closed or Open Loop
Mode. Closed Loop mode monitors the direct feedback sensor to ensure
accurate material displacement. Open Loop mode approximates material
displacement from vehicle speed as well as direct pump and material calibration
settings. To properly run the system in open loop mode the direct system must
use a positive displacement pump. The default value is Open Loop Mode.
Gain
The Gain menu item is a multiplier applied to closed loop direct operation, used
to fine-tune the direct system’s sensitivity to changes in vehicle speed or direct
set rate. A high gain value will cause the direct system to adapt to changes
quickly but might cause the system to overshoot the target RPM. A low gain
value will cause the direct system to adapt to changes slowly but might cause the
system to under apply material until it reaches the target RPM. The default value
is 100.