5100ex Calibration Manual
AutoCalibration of Prewet Liquid
38
STEP 11: Press the green, Standby knob to stop dispensing liquid. The status should
change to “Off”, as shown in Figure 8. If your system is an Open Loop system
the pulses will be 0.
Figure 8: Prewet AutoCal Screen after running
STEP 12: Press Next to continue to the next AutoCal screen. It should look like Figure 9
below:
Figure 9: Prewet AutoCal Enter Volume