2 Safety instructions
2.1 General safety instructions
PIOX S72*
2022-05-15, UMPIOX_S72xV1-9EN
8
2
Safety instructions
2.1
General safety instructions
Prior to any work, read the operating instruction carefully and in full.
Failure to comply with the instructions, in particular with the safety instructions, poses a risk to health and can lead to
material damages. For further information, contact FLEXIM.
During installation and operation of the measuring equipment, observe the ambient and installation conditions specified in
the documentation.
Explanation of symbols on the transmitter and accessories:
The measuring equipment has to be checked for proper condition and operational safety before each use. If troubles or
damages have occurred during installation or operation of the measuring equipment, please inform FLEXIM.
It is not allowed to make unauthorized modifications or alterations to the measuring equipment.
If the measuring point is within an explosive atmosphere, the danger zone and present explosive atmosphere have to be
determined. The transmitter, transducers and accessories have to be appropriate and approved for the conditions within
the corresponding zone.
Personnel has to be suitably trained and experienced for the work.
Observe the "Safety instructions for the use in explosive atmospheres" (see document SIFLUXUS). Observe the instructions
for hazardous substances and the respective safety data sheets. Observe the regulations for the disposal of electrical
equipment.
2.2
Intended use
The measuring equipment is intended for the measurement of fluid properties in closed pipes. By means of connected
transducers, the transit times of the ultrasonic signals in the fluid and the pipe as well as other related properties, such as
temperature and pressure, are measured and evaluated.
The transmitter uses these values to calculate the sought quantities, e.g., volumetric flow rate, mass flow rate, density and
concentration. Through comparison with the values stored in the transmitter, further physical quantities can be
determined. The physical quantities are provided via configurable outputs and the display.
• All instructions of this operating instruction have to be observed to ensure intended use.
• Any use beyond or other than the intended use is not covered by warranty and can present a danger. Any damage
arising from not intended use shall be solely the liability of the operator or user.
• The measurement is carried out without direct contact to the fluid in the pipe. The flow profile is not influenced.
• The transducers are fixed to the pipe using the supplied transducer mounting fixture.
symbol
explanation
direct current
connection for equipotential bonding/grounding
protective ground terminal
Electric devices must be disposed of separately. If necessary, additional hazardous substances are indicated for
disposal.
Warning! Electric shock possible.
Observe the operating instruction.
Warning! Observe the safety instructions in the manufacturer's documentation.
i
Содержание PIOX S72 Series
Страница 1: ...PIOX S72 UMPIOX_S72xV1 9EN Operating instruction...
Страница 6: ...Table of contents PIOX S72 2022 05 15 UMPIOX_S72xV1 9EN 6...
Страница 196: ...21 Settings 21 9 Key lock PIOX S72 2022 05 15 UMPIOX_S72xV1 9EN 196...
Страница 225: ......