19 Settings
19.1 Dialogs and menus
FLUXUS G722ST-HT
2021-09-01, UMFLUXUS_G722ST-HTV1-2EN
148
19
Settings
19.1
Dialogs and menus
• Select the menu item
Dialogs/Menus
in the program branch
Special functions
.
• Press ENTER.
Pipe circumference
• Select the menu item
Pipe circumference
.
• Select
Yes
if the pipe circumference is to be entered instead of the pipe diameter in the program branch
Parameters
.
• Press ENTER.
If
Yes
is selected for
Pipe circumference
, the outer pipe diameter will still be requested in the program branch
Parameters
.
• Press
to select the menu item
Pipe circumference
.
• Press ENTER.
The value displayed in the menu item
Pipe circumference
is calculated from the last displayed outer pipe diameter.
Example: 100 mm
.
π = 314.2 mm
• Enter the pipe circumference. The limits for the pipe circumference are calculated on the basis of the limits for the outer
pipe diameter.
• Press ENTER.
During the next scroll through the program branch
Parameters
, the outer pipe diameter that corresponds to the entered
pipe circumference will be displayed.
Example: 180 mm : π = 57.3 mm
Coating
If the pipe has a coating, the material parameters of the coating have to be entered in the program branch
Parameters
.
• Select the menu item
Edit coating
.
• Select
Yes
if the pipe has a coating.
• Press ENTER.
Lining 2
If the pipe has a second lining, the material parameters of the coating have to be entered in the program branch
Parameters
.
• Select the menu item
Edit Lining 2
.
• Select
Yes
if the pipe has 2 linings.
• Press ENTER.
Measuring point number
• Select the menu item
Measuring point no.
• Select
Number
if the measuring point number should only consist of numeric characters. Select
Text
if the measuring
point number should only consist of alphabetic characters.
• Press ENTER.
Special functions\Dialogs/Menus
Special functions\Dialogs/Menus\Pipe circumference
Special functions\Dialogs/Menus\Edit coating
Special functions\Dialogs/Menus\Edit Lining 2
Special functions\Dialogs/Menus\Measuring point no.
Содержание FLUXUS G722ST-HT
Страница 1: ...FLUXUS G722ST HT UMFLUXUS_G722ST HTV1 2EN Operating instruction...
Страница 6: ...Table of contents FLUXUS G722ST HT 2021 09 01 UMFLUXUS_G722ST HTV1 2EN 6...
Страница 173: ...Annex FLUXUS G722ST HT D Conformity declarations 173 UMFLUXUS_G722ST HTV1 2EN 2021 09 01 D Conformity declarations...
Страница 174: ...Annex D Conformity declarations FLUXUS G722ST HT 2021 09 01 UMFLUXUS_G722ST HTV1 2EN 174...
Страница 175: ......