14 Digital outputs
FLUXUS G722ST-HT
14.3 Configuration of a digital output as frequency output
123
UMFLUXUS_G722ST-HTV1-2EN, 2021-09-01
14.3
Configuration of a digital output as frequency output
The frequency output emits a square wave signal with a frequency which is proportional to the source item sent to the
output.
Assignment of a source item
• Select one of the following source items:
– Flow quantities
– Totalizers
– Fluid properties
– Diagnostic values
– Miscellaneous (Custom. Input 1...4)
• Select the source item to be transmitted to the output.
• Select a list item (here:
Flow quantities
).
• Press ENTER.
• Select a list item (here:
Volumetric flow rate
).
• Press ENTER.
• Select the list item
Values
.
• Press ENTER.
• Pass the menu item
Options\...\Outputs
with the following items in its entirety:
– Output range
– Error value
– Measuring range
– Output info
– Function test
For the description of the individual steps, see operating section 9.2.6.
Options\Outputs\Digital output B1\Source item
Options\Outputs\Digital output B1\Source item\Flow quantities
Options\Outputs\Digital output B1\Source item\...\Volumetric flow rate