EN
53
6.5 User interface
6.5.1 FIMER Installer for Solar Inverters
FIMER Installer for Solar Inverters APP allows to:
• Inverters commissioning and set the system parameters.
• Update the inverter firmware.
6.5.2 Integrated Web User Interface
The integrated Web UI is accessible via Wi-Fi channel by using
any wireless device (PC, smartphone, tabled,….) and allow to:
• Commission a single inverter.
• Advanced settings of system parameters.
• Update the inverter firmware.
6.5.3 Aurora Vision
®
Integrated logging capability allows remote monitoring of the plant
without the needs of any additional external loggers.
Aurora Vision is a cloud based platform enabling remote
monitoring and asset management of FIMER devices in range of
solar power application.
Aurora Vision consist of two different products, designed to meet
different market needs, an APIs Service (RESTful architecture)
to enabled third party data integration and a KIOSK view to show
publicly solar plant benefits and performances:
•
Plant Portfolio Manager
. An advanced professional web-portal
that allows stakeholders (such as installers/operators/managers)
to monitor and control fleets of photovoltaic systems installed for
final customers.
•
Energy Viewer
. A smart and easy-to-use mobile app for
monitoring the main power generation and self-performances
indicators, for owners of residential and commercial PV plants, in
order to keep energy use and savings in check.
•
APIs Service
. Harness the power of data from FIMER’s
photovoltaic systems to design solutions and provide
opportunities.
•
KIOSK View
. A public and customizable web page based on
HTML5 (self-updating and embeddable in external frames) to
show the benefits and performances of a solar power plant.
6.6 Measurement tolerance
The data supplied by the inverter may differ from measurements
taken by certified measuring instruments (e.g. output
meters, multimeters and grid analysers); since the inverter
is not a measuring instrument it has wider tolerances for the
measurements it makes.
The tolerances are generally:
• ±5% for real-time measurements with output power below 20%
• ±3% for real-time measurements with output power above 20%
• ±4% for all statistical data.