EN
23
3.7.3 Power derating due to altitude
The power reduction due to altitude can occour with temperature above 45°C.
PVS-10-TL; PVS-12.5-TL; PVS-15-TL
4000
11811
3500
11154
3000
10498
2500
9842
2000
9186
1500
8530
1000
7874
500
7217
0
6561
10
0
20
30
40
50
60
70
80
100
Altitude (m / ft)
Pout (%)
90
3.7.4 P-Q Capability
ATTENTION –
A
P-Q capability may be reduced to match the specific grid code requirements applicable in your country.
The following represents the maximum P-Q capability of the unit under the specified operating conditions.
PVS-10-TL
PVS-12.5-TL
PVS-15-TL
Ambient temperature
45 °C
Rated output voltage (Un)
380/400 Vac
Nominal Active Power (Pn)
10000 W
12500 W
15000 W
Nominal Apparent Power (Sn)
10000 VA
12500 VA
15000 VA
Nominal Reactive Power (Qn)
6000 VAR
7500 VAR
9000 VAR
Cosphi @ Sn
-0.8 ... 1 ... 0.8+
Capability with grid voltage
1.0 x Un
Q (%)
P (%)
-100
-90
-80
-70
-60
-50
-40
-30
-20
-10
0
+10
+20
+30
+40
+50
+60
+70
+80
+90
+100
10
20
30
40
50
60
70
90
100
80