EN
18
PVS-10-TL
PVS-12.5-TL
PVS-15-TL
Communication
Embedded communication interfaces
Dual port Ethernet, WLAN, RS485 port
Local User Interface
Synoptic, Web User Interface, Installer APP, Display (optional)
Communication protocol
Modbus TCP Sunspec, Modbus RTU Sunspec
Commissioning tool
Web User Interface, “Installer for solar inverters” mobile APP
Cloud services
Aurora Vision® Plant Portfolio Manager, Rest API
Advanced features
Embedded export limitation control (in combination with external
meter), 24h self consuption monitoring
Environmental
Operating ambient temperature range
-25...+60°C (-13...140 °F) with derating above 45 °C (113 °F)
Storage temperature
-40°C...+85°C / -40°F...185°F
Relative Humidity
4…100 % with condensation
Sound pressure level, typical
40 dB(A) @ 1m
45 dB(A) @ 1m
45 dB(A) @ 1m
Maximum operating altitude
4000 m (13123 ft) with output power [Pout ] linear derating above
2000m (6561 ft)
(5)
Environmental pollution degree
classification for external environments
3
Environmental class
Outdoor
Climatic category according to IEC 60721-3-4
4K26
Physical
Inverter typology
Grid connected, Double stage, Transformerless
Environmental Protection Rating
IP65
Cooling System
Natural
Dimension (H x W x D)
H = 568.2 mm / 22.37” (644mm / 25.35” with AC quick fit connector);
W = 473.6 mm / 18,64” ;
D = 207 mm / 8,15”
Weight
29.6 Kg / 65lb
Mounting system
Mounting bracket
Night-time consumption (active power / reactive power)
11W/ 110VAR
Minimum inverter feed-in power
5W
Overvoltage rating as per IEC 62109-1
II (DC input) III (AC output)
Safety
Safety class
I
Insulation Level
Transformerless
Marking
CE
(4)
,RCM
Safety, EMC and Radio Spectrum Standards
IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-1, EN 61000-6-2,
EN 61000-3-11, EN 61000-3-12, EN 62311, EN 301 489-1, EN
301 489-17, EN 300 328
Grid standard
(check the availability with your sales channel)
IEC 61683, EN 50530, IEC 62116, IEC 61727, AS/NZS 4777.2,
VDE-AR-N 4105, VDE-AR-N 4110, VDE V 0124-100, DIN VDE V
0126-1-1, VFR 2019, UTE C15-712-1, CEI 0-21, CEI 0-16, PEA,
MEA, EN 50438 (including Ireland deviation), EN 50549-1/-2, CNS
15382, DRRG (DUBAI), CLC/TS 50549-1/-2, TOR Erzeuger, G98,
G99, Synergrid C10/11, RD 413, RD 1565, RD244, P.O. 12.3, NTS
631, UNE 206006 IN (ITC-BT-40), PPDS-priloha, Denmark Type
A/B, IRR-DCC-MV, ABNT NBR 16149, ABNT NBR 16150, Chile
LV/MV, NRS 097-2-1, SII, ISO/IEC Guide 67, Netherlands Type A/B,
EIFS Type A
1. The AC voltage range may vary depending on specific country grid standards
2. The Frequency range may vary depending on specific country grid standards
3. Please refer to the document “String inverters – Product manual appendix” available at
for information on the quick-fit
connector brand and model used in the inverter
4. Hereby, FIMER S.p.A. declares that the radio equipments (radio module combined with the inverter), to which this user manual refers,
are in compliance with the Directive 2014/53/EU. The full text of the EU Declaration of Conformity is available at the following internet
address:
5. @ 4000m (45° C ambient temperature), the output power (Pout) is reduced by 15%.
6. In the event of a fault, limited by the external protection envisaged on the AC circuit
Features not specifically mentioned in this data sheet are not included in the product.