64
Festo — EXCH — 2022-03b
Mounting (vertical mounting position)
8.2.6
Eliminate warping in the planar surface gantry
Transport and mounting have caused warping in the planar surface gantry.
Warping causes malfunctions and increased wear.
• Relieve warping with the following steps.
9
10
12
13
13
14
15
14
Fig. 32: Relieve warping, e.g. EXCH-40
9
X-axis 2 without energy chain
10
Y-axis (cross-brace)
12
Motor-side drive cover
13
Guide carriage screws in slotted holes
14
Guide carriage
15
X-axis carriage
1. On X-axis 2 without energy chain:
Loosen the 8 screws of the 2 guide carriages 1 revolution.
2. Push the Y-axis (cross-brace) up and down through the complete stroke of the X-axes with 2
persons.
3. Unscrew the 8 screws one by one and screw them in again with LOCTITE 243 screw locking
compound and tighten. Tightening torque 5.9 Nm
Ensure tension-free alignment of the axes by unscrewing only one screw at a time.
Ä
Alignment of the planar surface gantry is completed.
Next step: adjust toothed belt pretensioning