38
Festo — EXCH — 2022-03b
Mounting (horizontal mounting position)
7.2.4
Preparation
WARNING
Danger of serious injuries.
The planar surface gantry will be detached from the mounting surface if the mounting is insufficient.
• Adjust only one screw of an adjusting kit at a time.
• Ensure that there is sufficient screw-in depth for the screws: for steel
³
8 mm.
2
1
3
Fig. 22: Mounting profile cover
1
Profile cover retaining screw
2
Profile cover of the X-axis
3
Energy chain of the X-axis
•
Demount the profile covers of the two X-axes:
–
Unscrew the retaining screws of the profile covers.
If required, move the already loosened energy chain.
–
Remove the profile covers.