5. Diagnosis
5-2
Festo P.BE-DLP-VSE-... en 0206a
5.1.2 Electric components
Error messages of the electric components
Indicator light
Setting of the fittings
Meaning
Indicator light does not light
up, although the fitting is in the
appropriate position.
– switch position
– Incorrect connection for limit
switch
– Limit switch does not supply a
signal
– Compressed air supply not cor-
rect.
– Fault in bus module
(only DLP-...-DP or -ASI)
– Indicator light defective
Both indicator lights light up
– basic position or
– switch position
– Incorrect connection for limit
switch
– Fault in bus module
(only DLP-...-DP or -ASI)
– Servicing required
Fig. 5/2: Indicator light displays showing the position of the fittings
5.1.3 Replacing the indicator lights
If the indicator lights for AUF/OPEN or ZU/CLOSE are defec-
tive, you can replace these yourself.
1. Unscrew the transparent part of the cap.
2. Replace the LED. Use a bulb remover here for
bulb type
BA9S
.
3. Screw the cap into place again.
Содержание DLP-VSE Series
Страница 1: ...Manual Local control unit DLP VSE DLP VSE DP DLP VSE ASI Manual 396 535 en 0206a...
Страница 2: ......
Страница 4: ...Contents and general instructions II Festo P BE DLP VSE en 0206a...
Страница 8: ...Contents and general instructions VI Festo P BE DLP VSE en 0206a...
Страница 20: ...1 Summary of components 1 8 Festo P BE DLP VSE en 0206a...
Страница 54: ...3 Installation 3 30 Festo P BE DLP VSE en 0206a...
Страница 84: ...4 Commissioning 4 30 Festo P BE DLP VSE en 0206a...
Страница 104: ...5 Diagnosis 5 20 Festo P BE DLP VSE en 0206a...
Страница 108: ...A Technical specifications and index A 4 Festo P BE DLP VSE en 0206a...