
4. Commissioning
4-24
Festo P.BE-DLP-VSE-... en 0206a
Request diagnostic information
The diagnostic data are requested by the Local control unit
with the function
Slave_Diag
. A description of this function
can be found in chapter 5.2, Diagnosis with PROFIBUS-DP.
Cyclic exchange of data
The cyclic exchange of data is carried out with function
Data_Exchange
. With this function, the output data for the
Local control unit are transferred as an octet string of length
x. The length of the octet string depends on the number of
identifier bytes.
Please note
With the function Data_Exchange the Local control unit
expects the output information for the valve and electric
outputs. The input information is sent as a reply telegram
to the master.
Summary of parameters (Data_Exchange):
Octet 1
I/O data byte_1
Bit 0 Input/output x*)
Bit 1 Input/output x*+1)
Bit 2 Input/output x*+2)
Bit 3 Input/output x*+3)
Bit 4 Input/output x*+4)
Bit 5 Input/output x*+5)
Bit 6 Input/output x*+6)
Bit 7 Input/output x*+7)
Octet 2
I-data byte_2
Bit 0 Input x+8
Bit 1 Input x+9
...
Bit 7 Input x+15
Содержание DLP-VSE Series
Страница 1: ...Manual Local control unit DLP VSE DLP VSE DP DLP VSE ASI Manual 396 535 en 0206a...
Страница 2: ......
Страница 4: ...Contents and general instructions II Festo P BE DLP VSE en 0206a...
Страница 8: ...Contents and general instructions VI Festo P BE DLP VSE en 0206a...
Страница 20: ...1 Summary of components 1 8 Festo P BE DLP VSE en 0206a...
Страница 54: ...3 Installation 3 30 Festo P BE DLP VSE en 0206a...
Страница 84: ...4 Commissioning 4 30 Festo P BE DLP VSE en 0206a...
Страница 104: ...5 Diagnosis 5 20 Festo P BE DLP VSE en 0206a...
Страница 108: ...A Technical specifications and index A 4 Festo P BE DLP VSE en 0206a...