3. Installation
3-14
Festo P.BE-DLP-VSE-... en 0206a
Setting the configuration
The Local control unit can be operated in the configurations
“with measurement bus” or “without measurement bus.” In
the configuration “with measurement bus” an analogue
measured value can be provided for the controller.
Set your desired configuration according to the following
diagram:
without measurement bus
with measurement bus
Fig. 3/19: Setting the configuration (4-element DIL switch)
Setting the station number
You can set the field bus station number with the 8-element
DIL switch.
Please note
Station numbers may only be assigned once per field bus
line.
Recommendation:
Assign the station numbers in ascending order. Assign the
station numbers, if necessary, to suit the machine structure of
your system.
The following station numbers are permitted:
Protocol
Address designation
Permitted station numbers
PROFIBUS-DP
PROFIBUS address
0; ...; 125