Basic rule 2
If only valves are used, the address assignment is
always as described in basic rule 1.
PLEASE NOTE
•
Maximum 26 solenoid valve coils
can be addressed.
•
There is no rounding up of the last two
positions on the valve side.
•
Unused inputs/outputs must be left free and
must not be used for other modules.
•
Valve terminals without input modules
also occupy input addresses of the
configured quarter or half rack.
Basic rule 3
If only electric I/Os are used, the address assign-
ment is always the same as in basic rule 1.
PLEASE NOTE
•
Counting begins immediately to the left
of the node.
•
There is no rounding up of the last
two positions on the valve side.
•
With all locations fitted (half rack configu-
ration), the terminal provides 64 inputs
(60 digital inputs and 4 status bits) or
48 digital outputs.
•
Unused inputs/outputs must be left free
and must not be used for other modules.
VIFB8 - 03/05
4. Commissioning
9809c
4-13
Содержание 03-FB-8 Series
Страница 15: ...VIFB8 03 05 General safety instructions XIV 9809c ...
Страница 16: ...1 SYSTEM SUMMARY VIFB8 03 05 1 System summary 9809c 1 1 ...
Страница 28: ...2 FITTING VIFB8 03 05 2 Fitting 9809c 2 1 ...
Страница 41: ...3 INSTALLATION VIFB8 03 05 3 Installation 9809c 3 1 ...
Страница 74: ...4 COMMISSIONING VIFB8 03 05 4 Commissioning 9809c 4 1 ...
Страница 96: ...5 DIAGNOSIS AND ERROR TREATMENT VIFB8 03 05 5 Diagnosis and error treatment 9809c 5 1 ...
Страница 110: ...TECHNICAL APPENDIX VIFB8 03 05 Appendix A 9809c A 1 ...
Страница 122: ...INDEX VIFB8 03 05 Appendix B 9809c B 1 ...
Страница 126: ...V Valves 1 5 Voltage Cable selection 3 4 3 17 3 24 Connecting 3 15 3 19 3 22 3 26 3 29 VIFB8 03 05 Appendix B 9809c B 5 ...
Страница 127: ...VIFB8 03 05 Appendix B B 6 9809c ...