Connection example type 03
The following diagram shows the connection of a
common 24 V supply for pins 1 and 2. Please
note that:
•
the outputs/valves must be protected against
short circuit/overload with an external 10 A
fuse
•
the supply to the electronic components and
inputs must be fused externally with 3.15 A
against short circuit/overload (recommenda-
tion)
•
the common tolerance of 24 V DC
±
10 %
must be observed
•
both pins for potential equalization must be
connected and equalizing currents must be
prevented
•
the operating voltage can be switched off
separately at pin 2 (valves/electrical outputs).
VIFB8 - 03/05