Valves
There is a yellow LED for each valve solenoid
coil. This LED shows the switching status of the
valve solenoid coil.
Yellow
LED
LED
Switch position
of solenoid coil
Meaning
Yellow off
Basic position
Logic 0 (no signal)
Yellow on
•
Switch position
or
•
basic position
Logic 1 (signal applied)
Logic 1 but:
•
Operating voltage of outputs is
below permitted tolerance range
(DC 21.6 V...26.4 V)
or
•
compressed air supply not correct
or
•
pilot exhaust blocked
or
•
call servicing personnel
Fig. 5/4: LED display – switching status of valve solenoid coil