4.10. CFG12: Read Mode - Filter
Byte
0
1
2
3
4
5
6
0x00
VALID-TIME
1
TR-ID
0x00
Default
0x0037
5,5sec.
0x01
0x00
0x00
0x01
Byte
7
8
9
10
11
12
13
Contents
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Default
VALID-TIME:
(0...65535 x 100 ms = 0 ms ... 6553,5 sec)
(OperatingMode.NotificationMode.Filter.TransponderValidTime)
(OperatingMode.ScanMode.Filter.TransponderValidTime)
The period of time during which a Transponder can’t be read a 2
nd
time.
Note:
Changing of VALID-TIME only becomes effective after writing configuration
block CFG12 to EEPROM and reset of the RF Controller with
TR-ID:
(only for Scan Mode and Notification Mode)
TR-ID sets the parameters for Transponder identification.
If several Transponders has the same content in the addressed data block, only one da-
taset will be generated.
Byte:
2
3
4
5
Function
TR-ID-
SOURCE
TR-ID-DB-ADR
TR-ID-DB-N
TR-ID-SOURCE:
(OperatingMode.Miscellaneous.TransponderIdentification.
Source)
Sets the data source for Transponder identification.
b0
data block
b1
Serial Number
TR-ID-DB-ADR
(OperatingMode.Miscellaneous.TransponderIdentification.
DataBlockNo)
Sets the address of the data block for Transponder identification. If ID-SOURCE
selects the Serial Number as data source, the ID-DB-ADR will be ignored.
TR-ID-DB-N
(OperatingMode.Miscellaneous.TransponderIdentification.
NoOfDataBlocks)
Sets the number of data blocks to be read for Transponder identification. If ID-
SOURCE selects the Serial Number as data source, the ID-DBN will be ignored.