Identification
Manual
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 32 of 153
H01113-4e-ID-B.docx
4.4. CFG3: RF-Interface
The parameters of the CFG3 configuration block contain global Transponder drivers and Reader
settings.
Byte
0
1
2
3
4
5
6
Contents
TAG-DRV
4
0x00
0x80
0x00
0x00
0x00
Default
0x0009
MR102-A /-B /-U
(0x0208
MR102-A /-B /-U)
0x0009
MR102-PoE
Byte
7
8
9
10
11
12
13
Contents
0x00
0x00
0x00
0x00
0x00
0x00
FU_COM
Default
0x00
TAG-DRV
1
:
Defines the Transponder types that are operated by the Reader.
Byte:
0
1
Bit:
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Driver
0
0
0
0
0
0
J
0
0
0
0
0
D
0
0
A
b0
Driver for the Transponder type is inactive
b1
Driver for the Transponder type is active
A:
(Transponder.Driver.HF.ICode1)
Driver for I-Code 1
D:
(Transponder.Driver.HF.ISO_15693)
Driver for ISO15693
J:
(Transponder.Driver.HF.ISO_18000-3M3)
Driver for ISO18000-3M3
In principle, only those Transponder drivers should be active that are used in the
actual application. Thus, the reaction time of the Reader for Transponder read- /
write-operations is reduced and the danger of a parasitic Transponder access is
minimized.
Note:
Two different firmware versions are available for the MR102-A /-B /-U.
- with support of IS I-code1
(Standard)
- with support of IS ISO18000-3M3
(Upgrade Code required)
The standard firmware for the MR102-E supports:
- IS I-Code1 + ISO18000-3M3
(Upgrade Code required)
4
A reasonableness check is performed by writing this parameter to the Reader. If an error occurs the Read-
er answers with STATUS = [0x11].