Identification
Manual
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 27 of 153
H01113-4e-ID-B.docx
Note:
TR-RESPONSE-TIME has no effect with the protocols for Reader Configuration and the
protocols for Reader Control.
The TR-
RESPONSE Time must be < “Block Timeout” in the Host COM-Port settings.
Protocol Mode:
..
( HostInterface.Miscellaneous.ProtocolSelection)
By setting of this parameter the Protocol Mode can be enabled
0x00:
support of Advanced Protocol Mode (default)
0x01:
support of Advanced and Standard Protocol Mode.
We recommend to use Advanced Protocol Mode
!
3.2. Serial Data Format and Protocol Frames
SCAN-INTERFACE: (
OperatingMode.ScanMode.Interface
)
Selection of the communication port for Scan-Mode
IF-NO:
Interface Number
b000:
RS232
b001:
RS485
b010:
USB
b011:
- do not use
–
b1xx:
- do not use
–
HID_DELAY:
By means of this parameter the data output in Scan-Mode (HID) can be delayed
if used with slow host systems.
HID_DELAY
Delay
b00
1 ms
b01
5 ms
b10
10 ms
b11
30 ms
Bit
7
6
5
4
3
2
1
0
Function
HID_DELAY
-
IF-NO