4.3. CFG2: Inputs / Outputs general
Via the following parameters the operation mode of the LED can be configured at any time. One
byte each is reserved for the active and mute position, by means of which the individual operation
modes according to the schedule below may be adjusted. In addition to this, for the active- and
mute position different flashing frequencies of the LED may be defined. So, the LED may be used
as an operation indicator.
Byte
0
1
2
3
4
5
6
Contents
0x00
0x00
0x00
IDLE-STATE
IDLE-FLASH
0x00
0x00
Default
0xA9
0x00
Byte
7
8
9
10
11
12
13
Contents
ACTIV-
STATE
ACTIV-
FLASH
ACTIV-
GRN-TIME
ACTIV-
RED-TIME
0x00
0x00
0x00
Default
0x26
0x00
0x0A
0x0A
1 sec.
1 sec.
Note:
The following configuration values are not valid for the ID ISC SPAD102.
The blue LED on the ID ISC SPAD102 will be active if the HF-field is active.
The blue LED on the ID ISC SPAD102 will flash slowly if a tag has been detected.
The Readers ID ISC.MR102 dispose of a two colored LED (red / green). The color or-
ange can be obtained by combining both basic colors red and green.
Colors
LED
Color:
red
green
red
1
0
green
0
1
orange
1