Identification
Manual
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 42 of 153
H01113-4e-ID-B.docx
BANK:
Memory bank of the Transponder which will be accessed by the Reader
Bit:
7
6
5
4
3
2
1
0
Function
0
0
0
0
0
0
BANK_NR
BANK_NR:
(
OperatingMode.ScanMode.DataSource.BankNo
)
(
OperatingMode.NotificationMode.DataSource.BankNo
)
In case of ISO18000-3M3 Transponder BANK_NR is defined as follows:
b00
reserved
b01
EPC memory bank
b10
TID memory bank
b11
User memory bank
DB-ADR
1
:
(OperatingMode.NotificationMode.DataSource.FirstDataBlock)
(OperatingMode.ScanMode.DataSource.FirstDataBlock)
0x00...0xFF
Address of first data block. Range: 0x00...0xFF.
DB-N
6
:
OperatingMode.NotificationMode.DataSource.NoOfDataBlocks
OperatingMode.ScanMode.DataSource.NoOfDataBlocks
Number of data blocks.
D-START:
(OperatingMode.ScanMode.DataSource.FirstByte)
This parameter defines the first byte in the raw data (defined by DB-ADR and D-LGT),
which will be transferred in Scan-Mode. To transfer the whole data block D-START must be
set to 0.
Note:
The size of one data block depends on the type of Transponder.
D-LGT:
OperatingMode.ScanMode.DataSource.NoOfBytes
D-LGT defines the length of raw data which are transmitted in the Scan-Mode.
Number of
data bytes
to be transferred, starting with the D-START.
Note:
The maximum number of data block bytes is limited to 64bytes
6
A plausibility check is performed by writing this parameter to the Reader. If an error occurs the Reader
answers with STATUS = [0x11].