Identification
Manual
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 90 of 153
H01113-4e-ID-B.docx
UID_LF:
If this bit is set the parameter UID_LNG must inserted into the protocol.
b0:
The protocol UID_LNG doesn't include the UID_LNG byte and
the UID field has a fixed length of 8 byte, from byte 6 to byte 13.
b1:
The protocol includes the parameter UID_LNG. The UID has a variable
length as defined in UID_LNG.
EXT_ADR:
If this bit is set the command includes extended address fields.
b0:
Transponder memory addressing is done by the 1 byte DB-ADR Field.
b1:
Transponder memory addressing is done by BANK and
2
byte DB-ADR
Field
READ_COMPLETE_BANK:
(ISO18000-3M3)
If this bit is set the reader will automatically read out all blocks of the selected
memory bank. Only available in the extended address mode.
b0:
Reader reads out the memory blocks according to the settings for DB-
ADR and DB-N
b1:
Read reads out the compete memory bank
Notes:
This functionality is limited to memory banks with a maximum size of 340 Byte.
UID_LNG:
Is a optional parameter and depends on the setting of UID_LF (see MODE). UID_LNG de-
fines the length of the following UID field.
UID:
Read-only serial number of the Transponder. The UID is required only in the addressed
mode.
BANK:
Memory bank of the Transponder which will be accessed by the Reader
Bit:
7
6
5
4
3
2
1
0
Function
A_FLAG
0
0
0
0
0
BANK_NR
BANK_NR:
In case of ISO18000-3M3 Transponder BANK_NR is defined as follows:
b00
reserved
b01
EPC memory bank
b10
TID memory bank
b11
User memory bank