Identification
Manual
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 49 of 153
H01113-4e-ID-B.docx
4.13.
CFG16: Persistence Reset
The parameters in CFG16 are used to configure the Reader reset timing of the persistence flags of
the Transponders. The timing for reset of the persistence flags is used by the Reader in Host Mode
and Scan Mode.
Byte
0
1
2
3
4
5
6
Contents
0x00
0x00
PER-RESET-TIME
0x00
0x00
0x00
Default
0x00
0x00
0x0028
0x00
0x00
0x00
40 x 5ms = 200ms
Byte
7
8
9
10
11
12
13
Contents
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Default
0x00
0x00
0x00
0x00
0x00
0x00
0x00
PER-RESET-TIME:
(Transponder.PersistenceReset.Antenna.No1.PersistenceResetTime)
The timer value specifies a time which determine the reset of the Transponder persistence
flags by the Reader. The timer PER-RESET-TIME starts after the Reader gets a response
at the antenna port. After this time has expired the Reader send a persistence reset com-
mand to the Transponders at the antenna port.
Timer ticks = 5ms
Maximum timer value = 5ms x 65534[0xFFFE] = 5,46125 min.
The value 65535 [0xFFFF] indicates that no persistence reset is performed by the Reader