H90202-7e-ID-B.docx
TR-DATA-3:
Selects the data types for read operation.
Bit
7
6
5
4
3
2
1
0
Function
-
-
-
-
READ_
COMPL
ETE_B
ANK
-
ANT-
STORE
COM
Prefix
COM Prefix: (Scan Mode only)
(OperatingMode.ScanMode.DataFormat.BusAddressPrefix)
b0:
no COM Prefix is send
b1:
The Reader will transmit the COM-ADR in front of each data set.
ANT-STORE:
(OperatingMode.BufferedReadMode.DataSelector.Mode.Enable_AntennaPool)
(OperatingMode.NotificationMode.DataSelector.Mode.Enable_AntennaPool)
(OperatingMode.ScanMode.DataSelector.Mode.Enable_AntennaPool)
If this bit is set, the reader stores only one data set also if a tag has been detected of
more than one multiplexer antenna. If this bit is not set, the reader stores a data set for
each multiplexer antenna.
Examples:
1) ANT-STORE = 1, Tag was detected by antenna 1 and 4
Antenna
8
7
6
5
4
3
2
1
Bit
7
6
5
4
3
2
1
0
detected
0
0
0
0
1
0
0
1
one data set, antenna number = 0x09
NOTE:
If ANT-STORE = 1 and a Tag was detected by antenna 1 and the data set was transmitted to
the host, the reader doesn't store new data sets for this transponder if read on another an-
tenna, if valid time was not expired.