PREFERRED_CHN: (AirInterface.Region.UHF.EU.Channel.EN302208_4_ChannelPlan.
PreferredChannels.ChannelNoX) x=1-4
Defines the preferred channels used by the European Reader.
NOTE:
These settings are only applicable if Region [0xFF] Unknown is selected.
These settings are only applicable for EU Readers.
DC-Power: (AirInterface.Antenna.UHF.Miscellaneous.Enable_DCPower)
Enables a 24 V DC Power on the antenna output to supply an external multiplexer via the
antenna cable.
Bit
7
6
5
4
3
2
1
0
Function
0
0
0
0
ANT4
ANT3
ANT2
ANT1
b0:
disabled (default)
24 V DC Voltage on antenna output is disabled
b1:
enabled
24 V DC Voltage on antenna output is enabled
NOTE:
This functionality is only available with the LRU3500.
DC-Power provides a voltage of 24 V DC and a maximum current of 500 mA.
If DC-Power is enabled no external power supply is needed to supply an external multiplex-
er.
Only multiplexers in the first cascade level can be supplied via the 24 V DC antenna voltag-
es.
CAUTION:
A direct connection of an antenna to an output with active DC-Power may damage the an-
tenna!
Byte
0
1
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Function
1. Pref Chn
2. Pref Chn
3. Pref Chn
4. Pref Chn