OBID
i-scan
®
UHF
Manual
ID ISC.LRU3000/3500
FEIG ELECTRONIC GmbH
Page 54 of 193
H90202-7e-ID-B.docx
TU-x: (OperatingMode.BufferedReadMode.Trigger.Source.Input.NoX.TriggerUse)
(OperatingMode.NotificationMode.Trigger.Source.Input.NoX.TriggerUse)
(OperatingMode.ScanMode.Trigger.Source.Input.NoX.TriggerUse)
X is the input which is used as a trigger (X=1-5)
b00
trigger not used
b01
trigger start the Reader operation
b10
trigger stops the Reader operation
b11
trigger start the Reader operation if the Reader is not in opera-
tion. In case of Reader is in operation a rising edge on the input
stops the Reader Operation.
TRIGGER_X-HOLD-TIME:
(OperatingMode.BufferedReadMode.Trigger.Source.Input.NoX.HoldTime)
(OperatingMode.NotificationMode.Trigger.Source.Input.NoX.HoldTime)
(OperatingMode.ScanMode.Trigger.Source.Input.NoX.HoldTime)
(1 ... 65535 * 100 ms = 100 ms ... 6553,5 sec)
The TRIGGER-HOLD-TIME defines the period in which the Reader performs inventory
commands and holds the RF Power active.
NOTE:
The time the RF field stays on is depending on the combination of the Trigger Condition
and the Hold Time