OBID
i-scan
®
UHF
Manual
ID ISC.LRU3000/3500
FEIG ELECTRONIC GmbH
Page 189 of 193
H90202-7e-ID-B.docx
Hex-value
Transponder Status
0X08
Authent Error
•
If access password is wrong
Hex-value
Parameter Status
0x10
EEPROM-Failure:
The EEPROM of the Reader is not able to be written on.
Before writing onto the EEPROM a faulty checksum of parameters has been detected.
0x11
Parameter-Range-Error:
The value range of the parameters was exceeded.
0x13
Login-Request:
Configuration access without having logged in to the Reader before.
0x14
Login-Error:
Login attempt with wrong password.
0x15
Read Protect:
The configuration block is reserved for future use.
0x16
Write Protect:
The configuration block is reserved for future use.
0x17
Firmware activation required:
The firmware must be activated first using ISOStart demo program and the command “Set Firmware
Upgrade”. The update code must be ordered by Feig Electronic.
1. Read the Device-ID using the command [0x66] Firmware version (Mode 0x80)
2. Send the Device-ID and the serial number of the reader to Feig Electronic
3. Write the upgrade code into the reader using the command [0x5F] Set Firmware Update
0x18
Wrong Firmware:
•
Firmwareversion conflict between RFC and FPGA
•
Conflict between the supported tagdrivers of RFC and FPGA
•
Readertype is not supported by the FPGA
•
Mismatch between RFC Firmware and Hardware
Hex-value
Interface Status
0x80
Unknown Command:
The Reader does not support the selected function.
0x81
Length-Error:
The selected function has the wrong number of parameters.
0x82
Command not available:
A Host command was sent to the Reader in the Buffered Read Mode.
A Buffered Read Mode protocol was sent to the Reader in the standard mode
The command with More bit does not correspond with the last command